Tunnel Diode Detector

With Integral Preamplifier

1 - 18 GHz


FEATURES:

SPECIFICATIONS: (@ +25°C)

Model Frequency
Range
(Ghz)
Minimum
Sensitivity
(K mV/mW)
Minimum
TSS
(dB)
Minimum
Flatness
(dB)
Maximum
VSWR
Outline
DTA182544
(NOTE 5)
1 - 18 10000
(NOTE 2)
-60
(NOTE 3)
± 1.5 2.0:1 See NOTE 5

NOTES:

  1. Negative output polarity standard. Add "P" to end of model number for positive output polarity.
  2. Sensitivity K for Square law Range up to -25dBm.
  3. TSS based on 2 MHz video bandwidth and 2dB video amplifier NF.
  4. DC bias requirement: +3.2±0.2 v, 30 mA nominal. (To avoid permanent damage the bias voltage shall not be greater than +3.4V.)
  5. Standard package style as outline 1, add letter "L" to end of model number for subminiature package outline 2.